81Chapter 4Define an analog voltage output range in proportion to the detected value.The full-scale is set in the range from 0 to 5.0V before shipment from the fac-tory.An analog voltage output range, inclination and other features of the detect-ed value can be entered.The setting method includes three variations, similar to the display scale:one-point scale, two-point scale, and INV.Or select the default setting to return to the factory shipment state.4.5.1 One-Point ScalingOnly the offset changes while the voltage output span (inclination) remainsunchanged. With one-point scaling, a "SLOPE" function is available withwhich the inclination reverses around the point designated for scaling.4.5 Analog Voltage Output ScaleOnly the voltage output can be changed with this function. To change thedisplayed value according to the detected value, use the display scale.However, if voltage (volts) is selected as a display unit, the indicationchanges after analog voltage output scaling.Notice5.25001.50005.00001.25000.5mm 2mm0Voltage(V)5.00000.25000.5mm 2mm0Voltage(V)0.5mm 2mm-2.2500Voltage(V)5.25001.50000.2500Change "0.5mm 1.2500" to "0.5mm 1.5000". Change the inclination with "SLOPE".