9 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION● Fine adjustment of the threshold can be performed in the measurement display.● Fine adjustment of the threshold can be performed even after teaching. sensing mode, rising differential mode or trailing differential mode>Automaticallyset after about 3seconds.Press the UP / DOWN key Press the UP / DOWN key Press the TEACH keyConfirmed● When the sensing output is set to window comparator mode, the display of“ ” and “ ” can be changed by pressing the TEACH key for 1 second.Change the thresh-old value Measurement displayPress the TEACHkey for 1 secondAutomatic● When performing a fine adjustment of the threshold of “ ” or ”, pressthe UP key or DOWN key. After “ ” or “ ” is displayed, the fine adjust-ment of the threshold can be performed.(Automatically set after about 3 seconds.)Press down UP /DOWN keyPress down UP /DOWN keyPress the TEACHkeyConfirmedAutomaticor10 PEAK / BOTTOM HOLD FUNCTION● The peak / bottom hold function, is for displaying the peak value and bottom value.● When the zero set function is executed while the peak / bottom hold function isset to “Peak hold” or “Bottom hold”, the held measured value will be reset.Digital Display Description FunctionHold functionreleaseReleases the hold status,and outputs the currentmeasured valuePeak hold Holds maximum mea-sured valueBottom hold Holds minimum measuredvaluePress the TEACH keyand UP key simultane-ously for 3 seconds. Press the TEACH keyPress down UP /DOWN keyConfirmedSelectAutomatically set afterabout 3 seconds.ororor11 ZERO SET FUNCTION● The zero set function is the function to compulsorily set the measured value to “zero”.● The zero set indicator (yellow) will turn ON when the zero set is valid.● When the zero set function is executed while the peak / bottom hold function isvalid, the held measured value will be reset.● When the display setting is set to Offset, the zero set function cannot be set.Press the UP key and DOWN keysimultaneously for 3 seconds.ConfirmedPress the UP key and DOWN keysimultaneously for 6 seconds.Automatic“ “ will be dis-played during thisperiod.12 KEY LOCK FUNCTION● The key lock function is to prevent acceptance of key operations, so that the con-ditions set in each setting mode are not changed accidentally.● When key operation is performed after the key lock is set, “ ” will be displayedon the digital display.Press the TEACH key and DOWNkey simultaneously for 3 seconds.AutomaticPress the TEACH key and DOWNkey simultaneously for 3 seconds.Automatic13 ERROR INDICATION● In case of errors, attempt the following measures.Error indication Description RemedyMeasured value blinksInsufficient amount of reflected light.The sensing object is out of the sensing range.Confirm that the sensing distance is within thespecification range.Adjust the installation angle of the sensor.Nonvolatile memory is damaged or passed itslife expectancy. Please contact our office.Load of the sensing output is short-circuitedcausing an over-current to flow. Turn OFF the power and check the load.The semiconductor laser is damaged orpassed its life expectancy. Please contact our office.• When zero set is set, the measurement isnot performed normally.• Since the display setting is set to “Offset”,the zero set function cannot be used.• Confirm that the sensing distance is withinthe specification range.• Set the display to any setting except “Offset.”During teaching, the measurement is not per-formed normally.Confirm that the sensing distance is within thespecification range.System error Please contact our office.14 SPECIFICATIONSType Measurementcenter 30mm typeMeasurementcenter 50mm typeMeasurement cen-ter 100mm typeMeasurement cen-ter 200mm typeMeasurement cen-ter 400mm typeModel No. Discrete wire HG-C1030L3-P HG-C1050L3-P HG-C1100L3-P HG-C1200L3-P HG-C1400L3-PM12 connector type HG-C1030L3-P-J HG-C1050L3-P-J HG-C1100L3-P-J HG-C1200L3-P-J HG-C1400L3-P-JMeasurement centerdistance 30mm 50mm 100mm 200mm 400mmMeasurement range ±5mm ±15mm ±35mm ±80mm ±200mmRepeatability 10μm 30μm 70μm 200μm3 0 0 μ m ( m e a s u r e -ment distance 200 to400mm)8 0 0 μ m ( m e a s u r e -ment distance 400 to600mm)Linearity ±0.1%F.S. ±0.2%F.S.±0.2%F.S. (measurementdistance 200 to 400mm)±0.3%F.S. (measurementdistance 400 to 600mm)Temperature characteristic 0.03%F.S./°CLight source Red semiconductor laser Class 2 [JIS / IEC / FDA (Note 2)]Max. output: 1mW, Emission peak wavelength: 655nmBeam diameter (Note 3) Approx.ø50μmApprox.ø70μmApprox.ø120μmApprox.ø300μmApprox.ø500μmSupply voltage 24V DC ±10%, Ripple P-P 10% or lessPower consumption 40mA or less (at 24V DC supply voltage)Control outputPNP open-collector transistor• Maximum source current: 50mA• Applied voltage: same as supply voltage (Between control output to +V)• Residual voltage: 1.5V or less (At 50mA source current)• Leakage current: 0.1 mA or lessOutput operation Switchable either Light-ON or Dark-ONShort-circuit protection Incorporated (Auto reset type)Response time Switchable between 1.5ms / 5ms / 10msIO-Link communication• IO-Link specification: Ver1.1• Baudrate: COM3 (230.4kbps)• Process data length: 4byteProtection IP67 (IEC)Degree of pollution 2Ambient temperature -10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°CAmbient humidity 35 to 85% RH, Storage: 35 to 85% RHAmbient illuminance Incandescent lamp: Acceptance surface illuminance 3,000lx or lessOperating altitude 2,000m or less (Note 4)Cable Discrete wire: 0.2mm2 4-core PVC cable, 2m longM12 connector type: 0.2mm2 4-core PVC cable, 0.3m long with connectorMaterial Enclosure: Aluminum die-cast, Front cover: AcrylicWeight Discrete wire: Approx. 30g (without cable), Approx. 80g (including cable)M12 connector type: Approx. 30g (without cable), Approx. 50g (including cable)Notes: 1) Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and measurement center dis-tance are used for unspecified measurement conditions. The subject is white ceramics.2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.3) This is the size in the measurement center distance. These values were defined by using 1/e2 (approx. 13.5%)of the center light intensity. Due to leak light outside the specified area, the reflectance around the detectingpoint may be higher than at the point and this may affect the measurement value.4) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0m.