7 I/O CIRCUIT● NPN TypeRefer to the HL-G1 Series User's Manual for RS-422/ 485 wiring.3.3V3.3V(Black) Output 1: OUT1(Brown) +V50mA max.(White) Output 2: OUT250mA max.(Gray) Output 3: OUT350mA max.(Pink / Purple) NPN / PNP type switching input(Pink) Timing Input: TM(Purple) Multiple input: MI(Blue) 0VLoadLoadLoadExternal connection exampleSensor headinternal circuit*1Externalpower supply3 to 24 VDCM a i n p o w e rsupply24 VDC ± 10%Ripple 0.5 V(peak-to-peak)included*1Non-voltage contactIN0VMain circuitLead wire color● PNP Type(Black) Output 1: OUT1(Brown) +V(White) Output 2: OUT2(Gray) Output 3: OUT3(Pink / Purple) NPN / PNPtype switching input(Pink) Timing Input: TM(Purple) Multiple input: MI(Blue) 0VExternal connection exampleSensor headinternal circuit*1Externalpower supply3 to 24 VDCM a i n p o w e rsupply24 VDC ± 10%Ripple 0.5 V(peak-to-peak)includedRefer to the HL-G1 Series User'sManual for RS-422 / 485 wiring.50mA max.50mA max.50mA max.*1Non-voltage contact or PNP transistor open collector outputIN0VIN0VorHigh [5V to 30V DC (inrush current of 0.04mA max.)]: EnabledLow [0 to 0.6V DC or open]: DisabledMain circuitLead wire colorLoadLoadLoad8 APPLICABLE STANDARDS / REGULATIONS● “SPECIFICATIONS” shows the product, the follow-ing standards/regulations are relevant.EC Directives: EMC directive 2004/108/EC• Make sure that the length of signal and powerlines connected to the product is less than 30m inorder to meet CE marking requirements.Attach a ferrite core to the head cable as shown.Recommended ferrite core: SEIWA ELECTRICMFG. Co., Ltd.E04SR200935AB or equivalent one.30mm max.● Contact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,GermanyCable extension High-function type: extendable to 20 m with an optional extension cable (sold separately).Mass Standard type Approx. 70g (without cable), approx. 320g (including cable), and approx. 380g (with packing)High-function type Approx. 70g (without cable), approx. 110g (including cable), and approx. 160g (with packing)Applicable standards Conforming to EMC DirectiveNotes: 1) The following measurement conditions are applied unless otherwise specified; power voltage: 24V DC, ambi-ent temperature: 20°C, sampling cycle: 500μs, average number of sampling times: 1,024 times, measure-ment center distance, and measurement object: Aluminum vapor deposition surface reflection mirror.2) The diameter is the size of the object at the measurement center distance and determined by 1/e2 (approxi-mately 13.5%) of the center beam intensity. The reflectance around the detecting point may be higher than atthe point due to leak light outside the specified area, and this may affect the measurement value.3) Variance is ±0.1%F.S. or less depending on the ambient illuminance.6 CAUTIONSConnections● Be sure to turn OFF the power supply before connecting or disconnecting anyconnectors.● When connecting or disconnecting the connectors, be sure to hold the connectorarea not to apply extra force to the cable.● Be careful not to touch terminals or to let foreign objects get in the connector afterdisconnecting connectors.● Be careful not to apply force to around the connector of sensor head cable andextension cable. Do not bend the cables near connectors, which causes discon-nection of the cable.● When moving the sensor head during operation, install not to bend the cable dur-ing movement. Use replaceable extensions cable where the cable needs to bebent.Wiring● Do not roll up the sensor cable (bundle in parallel) with other wirings. Keep it atleast 100mm away from other wires. Cables should be separated from high volt-age and power circuit lines. If it is unavoidable, shield it by running through a con-ductive material such as grounded electrical conduit.● Install the product as far away as possible fromnoise source such as high-voltage lines, high-voltage device, power lines, power device,machines which generate a large starting andstopping surge, welding machines and invertermotor.● Do not pull the cable with a force more than29.4N when wiring the cable when the sensorhead is fixed. The cable may be bent with a ra-dius of 30mm or over. However, do not bend thecable within 20mm of the sensor head.20mm min.R30mm min.Warming Up● Allow at least 30 minutes of warming up after turning on the power to ensure theperformance of the product.Environment● Mount the sensor head to an aluminum or steel plate with a minimum surfacearea of 200cm 2 if the ambient temperature is 40°C or higher. In the case of install-ing two or more sensor heads in parallel, mount each sensor head to an alumi-num or steel plate with a minimum surface area of 200cm 2 and make sure that theambient temperature does not exceed 40°C.● The life of the semiconductor laser depends on the ambient temperature duringuse. When using the product near a heat source, take measures to keep the am-bient temperature of the sensor head as lower as possible. Mount the sensor on adevice having good heat radiation because the sensor itself also generates heat.● Keep the emitter surface and the receiver surface clean, not to attach light refrac-tors such as water, oil and fingerprints, or light blockers such as dust and dirt.When cleaning these parts, wipe them off using a soft lint-free cloth or lens clean-ing paper.● Install the sensor head at where extraneous light (such as sunlight or light whichhas the same wavelength as laser beam) do not enter the receiver. If high accu-racy is required, install a light shield plate or the like on the sensor head.● The sensor head has protection against immersion, while the connectors are notstructurally dustproof, waterproof, or corrosion-resistant. Do not use the productunderwater or in the rain.● Do not use the product in dusty places or that exposed to flammable or corrosivegases, droplet, direct sunlight, severe vibration or impact.http://panasonic.net/id/pidsx/globalOverseas Sales Division (Head Office)2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, JapanPhone: +81-568-33-7861 FAX: +81-568-33-8591About our sale network, please visit our website.PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2013 |
Related manuals for Panasonic HL-G1*A-RA-C5 Series
Panasonic HL-G1-A-C5 Series Instruction Manual
Panasonic HL-G1 Series Instruction Manual
Panasonic HL-C2C Series Instruction Manual
Panasonic LS-H A Series Instruction Manual
Panasonic HG-C Series Instruction Manual
Panasonic GX-M Series Instruction Manual
Panasonic HG-S Series Instruction Manual
Panasonic LS-H F-A Series Instruction Manual
Panasonic PE Series Instruction Manual
Panasonic PE Series Instruction Manual
manualsdatabase
Your AI-powered manual search engine