143.4 For Input Connection●Pulse input・Contact inputUse highly reliable metal plated contacts. Since the contact’s bounce time leads directly to error inthe count value, use contacts with as short a bounce time as possible. In general, select 30Hz formax.counting speed.・Non-contact input (Transistor input)Connect with an open collector. Use the transistor with the following specifications.VCEO=20V min. IC =20mA min. ICBO=6μA maxUse transistors with a residual voltage of less than 3V when the transistor is ON.*`Short-circuit impedance should be less than 1kΩ.Open-circuit impedance should be more than 100kΩ.(When the impedance is 0Ω, drain current is approx. 10mA.)・Input wiringPlease wire as short as possible by using a shielded wire or a metallic electric wire tube individually.3.5 For Output Connection●PhotoMOS relay output・It adopts PhotoMOS relay output, there is no polarity.Output: Rated capacity 30V AC/DC, 0.1A・Do not connect devices that voltage or load exceeds the rated capacity (30V AC/DC,0.1A)・Please wire less than 100m fir output.If it is long, it may not work correctly due to floating capacitance.Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com