136Error message Possible cause RecoveryScannerADF is busy! To scan or prescan, click RETRY on themessage window.To cancel, click CANCEL on the messagewindow.ADF is being used.Help file is not found Help file is not found.File Not FoundMemory Allocation Error!Path Not FoundMemory is insufficient.File or Path is not found.Close the application which controls thescanner, turn off the system(scanner/printer/computer), then turn onagain.Reinstall the KX-PS8000 software.TroubleshootingFile or Path is not found. Reinstall the KX-PS8000 software.Close the application which controls thescanner, turn off the system(scanner/printer/computer), then turn it onagain.File open error!!Failed to load the data of thegamma correction.Gamma data read error!!File write error!!Failed to transfer the file forscanning.Increase the hard disk space, then re-scan.Reinstall the KX-PS8000 software.Click Yes or No on the message window.Yes: Makes the width of the scan areasmaller, so that it can be scanned.No: The width of the scan area remainssame. Decrease the scanningresolution, then re-scan.The width of the scan area is toolarge.Horizontal scan area istoo big. Would you like tochange the horizontalscan size that will be ableto scan?Pcom95.dll internal error hasoccurred.PCOM95. DLL FunctionError!!PCom95.DLL was notfound!!The file Pcom95.dll is not found.PCOM31. DLL FunctionError!!Pcom31.dll internal error hasoccurred.PCom31.DLL was notfound!!The file Pcom31.dll is not found.No ASPI managers areloaded. This typicallyoccurs when a DOS ASPImanager is not resident inmemory.SCSI board is not correctly set. Correctly set the SCSI board in thecomputer. (Refer to the instructionsmanual of the SCSI board.)For any other trouble related to SCSI,refer to the SCSI section ofTroubleshooting ( + P.147).