5KX-TDE200GR3 Specifications3.1. General Description3.2. CharacteristicsControl Bus Original bus (16 bit, 8 MHz,10 megabytes per second)Communication Bus H.100 bus conformity (1024 time slot)Switching Non BlockingPower Input PSU-S 100 V AC to 130 V AC; 1.4 A/200 V AC to 240 V AC; 0.8 A; 50 Hz/60 HzPSU-M 100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50 Hz/60 HzPSU-L 100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50 Hz/60 HzExternal Battery +36 V DC (+12 V DC x 3, recommended maximum capacity is 28 Ah)Maximum Power Failure Tolerance 300 ms (without using backup batteries)Memory Backup Duration 7 yearsDialling Trunk Dial Pulse (DP) 10 pps, 20 ppsTone (DTMF) DiallingExtension Dial Pulse (DP) 10 pps, 20 ppsTone (DTMF) DiallingMode Conversion DP-DTMF, DTMF-DPRing Frequency 20 Hz/25 Hz (selectable)Trunk Loop Limit 1600 Ω maximumOperatingEnvironmentTemperature 0 °C to 40 °CHumidity 10%to 90% (non condensing)Conference Call Trunk From 10 x 3-party conference call to 4 x 8-party conference callMusic on Hold (MOH) 2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)MOH1: External Music Source portMOH2: Selectable Internal/External Music Source portPaging Internal Level Control: -15 dB to +6 dB in 3 dB stepsExternal 2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)Serial Interface Port RS-232C 1 (max 115.2 kbps)LAN I/F RJ45 2 (10BASE-T/100BASE-TX)Extension Connection Cable SLT 1 pair wire (T, R)DPT 1-pair wire (D1, D2) or2-pair wire (T, R, D1, D2)APT 2-pair wire (T, R, D1, D2)PT-interface CS 1-pair wire (D1, D2)DSS Consoles and Add-on Key Module 1-pair wire (D1, D2)Dimension KX-TDE200NE 430 mm (W) x415 mm (H) x 276 mm (D)(17 1/5 in x 16 3/5 in x 10 7/8 in)Weight (when fully mounted) KX-TDE200NE Under 16 kg (35.2 lb)Terminal Equipment Loop Limit • PT: KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40Ω• SLT: 600 Ω including set• Doorphone: 20 Ω• . CS: 130Ω; PT-interface CS: 65ΩMinimum Leakage Resistance 15000 Ω maximumMaximum Number of ExtensionInstruments per Line1 for PT or SLT2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT3 by Digital eXtra Device Port connection of 2 DPTs and an SLTRing Voltage 75 Vrms at 20 Hz/25 Hz depending on the Ringing LoadTrunk Loop Limit 1600 Ω maximumHookswitch Flash/Recall Timing Range 24 ms to 2032 msBRI Cards Internal ISDN Mode Supply Voltage: 40 VPower Supply (BRI4): 4.5 W per 1 line, 10 W per 4 linesPower Supply (BRI8): 4.5 W per 1 line, 20 W per 8 linesPower Supply Method: Phantom Power SupplyDoor Opener Current Limit 24 V DC/30 V AC, 1 A maximumExternal Relay Current Limit 24 V DC/30 V AC, 1 A maximumExternal Sensor Current Limit Power to the external sensor is provided from the EIO4 card and must be grounded throughthe EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBXdetects input from the sensor when the signal is under 100Ω.Paging Terminal Impedance 600 ΩMOH (Music on Hold) Terminal Impedance 10000 Ω