1-21 Single-Type1-1. Unit SpecificationsHigh Static Pressure Ducted Type S-200PE2E5 / U-200PE2E8AINDOOR MODEL S-200PE2E5PANEL MODEL -OUTDOOR MODEL U-200PE2E8ABranch pipe MODEL -Performance test condition ISO13253 / EN14511 / EN12102Power supply Ø, Hz 1Ø 50Hz 3Ø 50HzV 220V 230V 240V 380V 400V 415V Min MaxCOOLINGCapacity kW 19.5 19.5 19.5 5.4 22.4BTU/h 66500 66500 66500 18400 76400Current A 1.95 1.90 1.85 9.75 9.35 9.00 - -Input power W 305 305 305 5.965k 5.965k 5.965k - -TOTAL W - 6.270k 6.270k 6.270k - -Annual consumption TOTAL kWh *4 - - - - 3135 - - -EER/EER CLASS TOTAL (W/W) *5 / ("A"~"G") - - - 3.11 3.11/B 3.11 - -Erp*6Pdesign kW - - - - - -SEER (W/W) - - - - - -Annual consumption kWh - - - - - -Class - - - - - -Power factor % - - - 93 92 92Noise indoor dB-A (H/M/L) 43/41/38Power Level dB 75/73/70Noise outdoor dB-A (H/L) 60/-Power Level dB 78/-HEATINGCapacity kW 22.4 22.4 22.4 5.6 25.0BTU/h 76400 76400 76400 19100 85300Current A 1.95 1.90 1.85 9.85 9.45 9.10 - -Input power W 305 305 305 6.015k 6.015k 6.015k - -TOTAL W - 6.320k 6.320k 6.320k - -COP/COP CLASS TOTAL (W/W) *5/ ("A"~"G") - - - 3.54 3.54/B 3.54 - -Erp*6Pdesign at -10°C kW - - - - - -Tbivalent °C - - - - - -SCOP (W/W) - - - - - -Annual consumption kWh - - - - - -Class - - - - - -Power factor % - - - 93 92 92Noise indoor dB-A (H/M/L) 43/41/38 -Power Level dB 75/73/70 -Noise outdoor dB-A (H/L) - 62/-Power Level dB - 80/-EXTRA LOW TEMP Total capacity(kW)/Input power(W)/COP -Max Current(A) / Max Input power(W) 6.90/1.27k 6.60/1.27k 6.30/1.27k 20.0/12.2k 20.0/12.8k 20.0/13.2k /Startring current(A) / Comp output(W) - - - 9.85/4.2k 9.45/4.2k 9.10/4.2k /Network Impedance(ΩMAX.) - -Fan motor output (Indoor/Outdoor) W 560 120 × 2 /Moisture removal volume L/h(Pt/h) 11.1 (23.3) -External static pressure Pa 60 / (140/270)IndoorAir flowCooling m3/min (m3/h) (H/M/L) 56/51/44 (3360/3060/2640)Heating m3/min (m3/h) (H/M/L) 56/51/44 (3360/3060/2640)OutdoorAir flowCooling m 3 /min (m 3 /h) 164 (9840)Heating m3 /min (m 3 /h) 164 (9840)Refrigerrant type / amount g(oz) R410A 56.0k (197.5) /Product dimensionHeight mm(inch) 479 (18-27/32) 1500 (59-1/16) /Width mm(inch) 1453 (57-7/32) 980 (38-37/64) /Depth mm(inch) 1205 (47-7/16) 370 (14-9/16) /Packing dimensionHeight mm(inch) 614 (24-3/16) 1642 (64-41/64) /Width mm(inch) 1536 (60-15/32) 1095 (43-7/64) /Depth mm(inch) 1339 (52-23/32) 529 (20-53/64) /Weight (NET) kg(lb) 100 (221) 127 (280) /(GROSS) kg(lb) 132 (291) 139 (306) /Layers limit (actually) 4 (5) 1 (2)Operation condition Cool (DBT) 18°C ~ 32°C -15°C ~ 46°CHeat (DBT) 16°C ~ 30°C -20°C ~ 24°CPIPINGPipe diameter mm (inch) (Liquid)Ø9.52(3/8) (Gas)Ø25.4(1) (Liquid)Ø9.52(3/8) (Gas)Ø25.4(1)Connecting method, Standard length m (ft) (Liquid)&(Gas)brazing connection, 7.5(24.6) (Liquid)flared type (Gas)brazing connection, 7.5(24.6)Pipe length range m (ft) 5~120m (16.4~393.7)Indoor unit & Outdoor unit height difference m (ft) 30m(Outdoor unit located lower)/30m(Outdoor unit located higher) (98.4/98.4)Add gas amount g/m (oz/ft) (Liquid)Ø9.52(3/8): 50g (0.54)Pipe length for additional gas m (ft) 30m (98.4)*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m3 /min.) shall be multiplied by 16.7 and rounded down the decimal point.*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage230V shall be used.*3 Network Impedance shall be applicable for EUROPE and CHINA models.*4 The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.*5 EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,Other fiche data indicates in an attached sheet.