24 InitializingYou can initialize all disk contents including image dataand/or setup data. Initializing All Contents & Setup DataWarning! The following are irrevocable procedures. Westrongly recommend that you copy important pic-tures from the hard disk.1. Press the [REC STOP] button or [STOP] button to stoprecording or playback.2. Turn off the power.3. Set MODE switches #1 through 4 on the rear panel asfollows:#1: ON#2: OFF#3: OFF#4: ON4. Turn on the power.The disk contents and setup data are initialized.Notes:• This will take about 40 minutes.• When finished, be sure to carry out step 5.5. Turn off the power, and return the MODE switches tothe previous positions. Then turn on the recorder. Initializing Setup Data1. Open the SYSTEM INFORMATION window, then movethe cursor to DEFAULT.2. Press the JogDial to move the cursor to SET.3. Press the JogDial.4. Select YES with the JogDial.YES: Initializing of setup data is enabled.5. Press the JogDial.SET DONE appears on the monitor after initializing.6. Press the [SETUP/ESC] button.The cursor moves to DEFAULT.7. Hold down the [SETUP/ESC] button for 2 seconds toquit the setup.Notes:• After closing the setup menu, the system may auto-matically restart if any parameter on the networkhas been changed.• The menu shown above is based on the assumptionthat an optional HDD is installed in the recorder. Asshipped from the factory, the hour meter is set to 1and the capacity to half. Initializing Settings for NetworkSetup Menu1. Stop recording or playback ifapplicable, and turn off thepower.2. Set the MODE switches asshown in the figure.3. Turn on the power. Wait for a few minutes until initializ-ing is completed.4. Return the MODE switches to the previous positions.Then press the [STOP] button.Note: These procedures reset the settings exclusivelyfor network setup menus: USER SETUP, HOSTSETUP, FTP SETUP, MAIL SETUP, and NETWORKVIDEO SETUP.MODEONONOFF1 2 3 4 5 6NOW FORMATTING HDDFORMAT FINISHEDPLEASE TURN OFF MODESW AND RESTARTSYSTEM INFORMATIONHDD1 HOUR METER 10000HHDD2 HOUR METER 10000HHDD CAPACITY XXX.XXGDEFAULT→ SET→SYSTEM VERSION X.XXSYSTEM LOGOMODE1 2 3 4 5 6ON