557. Move the cursor to the DYNAMIC REC parameter bypressing the D or C button, then select the recordingpattern for post-recording by pressing the + or - but-ton.OFF: Records the images assigned to group inputs,including the one that has activated the alarm (thesame as pre-recording).ALM-ONLY: Records the particular image that has acti-vated the alarm.The factory default setting is OFF.8. Move the cursor to the AUTO COPY parameter bypressing the D or C button, then select alarm backupmode by pressing the + or - button.OFF: Disables alarm data backup.ON: Enables alarm data backup.The factory default setting is OFF.9. Press the SETUP/ESC button to return to the previousprogram number menu.■ One Shot Recording (Internal Timer)As described before, the One Shot Recording is an eventrecording function reacting to an alarm input.It records the number of particular images that have acti-vated the alarm.These items let you determine the recording parameters forOne Shot Recording assigned in the program numbermenu.(continued from Program Timer)1. Select the recording mode O/S in the program numbermenu by pressing the + or - button, then press theSET button.The selected One Shot Recording menu as shownbelow appears on the monitor screen.2. Move the cursor to the TRIGGER ACTION parameter inthe menu by pressing the D or C button, then selectan active mode for group cameras when an alarm isreceived by pressing the + or - button.REC+ALM: Enables alarm recording and alarm activa-tion.REC: Enables only alarm recording.The ALARM display on the monitor is also disabled.The factory default setting is REC+ALM.3. Move the cursor to the REC RATE parameter in themenu by pressing the D or C button, then select thedesired recording rate by pressing the + or - button.1 - 60FPS: Records the selected number of the freezeimage per second.The factory default setting is 15FPS.Notes:• The maximum recording rate depends on theselected parameters in the COMMON SETUP menuas shown in the table.FIELD/FRAME CAMERA GENLOCK REC RATEFIELD ON 60FPSOFF 30FPSFRAME 3DIM ON 10FPSON OFF 10FPSFRAME 3DIM ON 30FPSOFF OFF 15FPS• “FPS” indicates as field per second or frame persecond when the FIELD/FRAME parameter is set toFIELD or FRAME in the menu.4. Move the cursor to the REC QUALITY parameter bypressing the D or C button, then select the desiredimage quality by pressing the + or - button.SUPER FINE: For enhanced sharpness (CompressionRate 1/6)FINE: For fine image quality (Compression Rate 1/10)NORMAL: For normal image quality (Compression Rate1/16)EXTENDED: For extended time recording quality(Compression Rate 1/25)The factory default setting is SUPER FINE.5. Move the cursor to the PICTURE parameter by pressingthe D or C button, then select the number of freezeimages to be recorded by pressing the + or - button.4 to 60: Records the selected number of freeze imagesfor One Shot Recording.The factory default setting is 16.6. Move the cursor to the AUTO COPY parameter bypressing the D or C button, then select an alarm back-up mode by pressing the + or - button.OFF: Disables backup for alarm recording.ON: Enables backup for alarm recording.The factory default setting is OFF.7. Press the SETUP/ESC button to return to the previousprogram number menu.3-1-1-1 PROG1-NO1-G1 REC SETUPO/S(EVENT:ONE SHOT)TRIGGER ACTION REC+ALMREC MODEREC RATE 15FPSREC QUALITY SUPER FINEPICTURES 16AUTO COPY OFF