14NO. name description○8 manual wirefeeding button●The function is used to feed welding wire into the liner before weldingby holding this key.・ manual wire feeding speed is decided by the welding current.○9 switching button●To switch the setting among“ initial ”, “ Weld ”, “ crater ” current.・For crater OFF, it can not be switched. Only the setting for “ Weld ”current can be selected.○10 gas check button● It is to check shield gas and adjust flow rate.• Normally, the indicator lamp is off. The lamp is on while checking gas.• To perform the gas check, press this button and then release, then the gasvalve of the wire feeder is turned ON and then turned OFF in 20 seconds.Press this button once again to terminate the gas check immediately.○11 lock button● During stand-by, long press button for 1 second to lock the panel. Thenall buttons on the panel expect ○3 ○6 ○8 ○9 ○10 can NOT be operated but thewire feeder potentiometer can be adjusted.○12 mode selectbutton● Weld: welding condition setting for ○2 ~○7 , ○9 and ○13 ~○17 , ○8 ○10for wire feeding check, gas check for welding, ○11 for panel lock・F. Adj: fine adjustment on F. Adj menu ( Section 5.4).・ Call: To call the welding condition being recorded ( Section 5.4).・ Record: To record the present welding conditions ( Section 5.4).○13 welding control●For welding control method selection, ( Chapter 8 )・ crater OFF: regular welding.・ crater ON: regular welding ~ crater welding.・ initial ON: initial welding ~regular welding ~ crater welding.・ spot welding: The welding lasts certain seconds according to the spotwelding time being set. The welding stops automatically when the spotwelding time is up.○14 welding method●To select the welding method・ pulse OFF: No pulse during welding.・ pulse ON: pulse is turned on during welding.・ root welding: NO pulse root welding 1.※・ Deepen: NO pulse deep penetration 1.※○15 material ● select the material to be welded・OP1 and OP2 are reserved for special design.○7 Jog-dial● When Mode selection key ○12 is set to“ Weld ”, (please refer to thedescription in ○6)・ When key ○6 selects different options, please adjust corrosponding setvalue according different items.・ During welding, the contents in ○8 can be adjusted. However,“ initial ” and “ crater ” current change not be changed.●When Mode selection key ○12 is set to “F. Adj”, ( Section 5.4)・ Refer to detailed description.●When Mode selection key ○12 is set to “ Call ”,・ select Call channel number. (Only the channel number being recordedin ○5 can be shown. )●When Mode selection key ○12 is set to “ Record ”,・ Record channel number is select.Names and functions