10CONNECTIONWelding Source Switch BoxBe sure to observe the following in order to avoid a burn or an accident resulting in injuryor death. Prior to connection work, be sure to turn off the switch of the switch box and makesure or safety. Do not touch with a wet hand. Electrical connection work and grounding work should be carried out by a qualified .In order to prevent a fire or burn-out of the device due to overheat of the cable or to preventgeneration of unstable arc。 Use the cable of the specified thickness or more. (Refer to page 10) Do not place a heavy substance on the cable or bring it into contact with a weld Zone. Tighten securely a cable joint. This machine has input power frequency select switch. Please confirm the correctposition of the switch. (Refer to pages 27,28 and 30.) When a frequency changes depending on where you use the welding source, switch toan adequate frequency.Welding TorchBase MetalSafety Warning① Loose the left and rightscrews to remove the cover.⑤Connect input cables(3 of them) tothe switch with fuse or no-fusebreaker (or leakage breaker).② Connect the inputcables (3 of them) tothe input terminals.3-phase ratedinput voltage③Tape around any exposedconductive sections whichmay come into contact withother partsWelding Power SourceSwitchBoxCoverInput⑥Ground with cable④Attach the coverCaution