Customizing G.703-Compatible Units4-2 7915-A2-GB20-20September 1997 Enter “?” to redisplay the menu. The CP unit is also known as an SDSL Termination Unit - Remote (STU-R). Aunit on the CO side is an SDSL Termination Unit - Central (STU-C). Option 6on the Main Menu varies according to unit type: on a CO unit it is used tomonitor the CP unit (STU-R) and on a CP unit it is used to monitor the CO(STU-C). This guide depicts the system terminal menus as they appear from a CP unit(unless otherwise noted). This is the default configuration for Model 7915standalone units.Making Changes from the Terminal InterfaceThe Board Configuration menu displays the current board software and hardwaresettings. It also allows you to change certain parameters on the board.This function is affected by the status of the switchpack (DIP switch control)setting. When operating in Terminal Mode (the system default) you can makeconfiguration changes through the terminal menus. When operating in Switchpack Mode, you can display configurationparameters using the terminal menus, but any configuration changes must bemade using the switchpacks on the board hardware. Refer toMakingChanges in Switchpack Mode on page 4-5.From the Main Menu, select option 3, Board Configuration.The following example shows the menu that appears on a CP unit.Command→ 3Board Configuration:–––––––––––––––––––1) SDSL Card Type – CPSDSL Rate Type – E12) E1 Line Encode – HDB33) Framing – FramedSDSL FW Rev – 02Globespan FW Rev – 1.07CP Serial # – 088165–––––––––––––––––––––––––––––––––––––––––––––––––––––––1–3) Board Configuration4) Switchpack Definitions?) Prints Board Configuration and this menuQ) QuitConfig→