E-4 Technical Specifications - Power StackAC30 series Variable Speed DriveAC FED ELECTRICAL RATINGSPower Supply = 380-480V ±10%, 50/60Hz ±5%, PSCC = 18kAMotor power, output current and input current must not be exceeded under steady state operating conditions.Minimum repetitive power up / power down cycle time = 10 minsFrameSize Product Code400V, 50Hz AC input ratings 460V, 60Hz AC input ratingsEst.Eff(%)SwitchingFrequency(kHz)nom / maxOutputCurrentDerate(%/kHz)MotorPower(kW)OutputCurrent(A)InputCurrent(A)MotorPower(hp)OutputCurrent(A)InputCurrent(A)KNormal Duty (Output Overload Motoring 110% for 60s)710-4K0315… 160 315 276 250 302 279 98 2 / 8 8.5710-4K0380… 200 380 343 300 361 333 98 2 / 8 7.7710-4K0440… 250 440 428 350 414 389 98 2 / 8 8.3Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 3s short term rating)710-4K0315… 132 260 229 200 240 225 98 2 / 8 7.7710-4K0380… 160 315 276 250 302 279 98 2 / 8 6.9710-4K0440… 200 380 344 300 361 334 98 2 / 8 7.5Power Supply = 380-480V ±10%, 50/60Hz ±5%, PSCC = 30kAMotor power, output current and input current must not be exceeded under steady state operating conditions.Minimum repetitive power up / power down cycle time = 10 minsFrameSize Product Code400V, 50Hz AC input ratings 460V, 60Hz AC input ratings Est.Eff(%)SwitchingFrequency(kHz)nom / maxOutputCurrentDerate(%/kHz)MotorPower(kW)OutputCurrent(A)InputCurrent(A)MotorPower(hp)OutputCurrent(A)InputCurrent(A)LNormal Duty (Output Overload Motoring 110% for 60s)710-4L0530… 280 530 480 450 520 498 98 2 / 8 8.8710-4L0590… 315 590 539 500 590 550 98 2 / 8 9.2Heavy Duty (Output Overload Motoring 150% for 60s)710-4L0530… 250 480 429 400 480 443 98 2 / 8 8.3710-4L0590… 280 530 478 450 520 497 98 2 / 8 8.5