Safe Torque Off 8-1AC30 series Variable Speed InverterChapter 8: Safe Torque Off SIL3/PLeGeneral InformationTHIS EQUIPMENT IF USED INCORRECTLY IS POTENTIALLY DANGEROUS. THEREFORE UNDER NO CIRCUMSTANCESSHOULD IT BE USED BEFORE THESE INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD BY THE END USER WHOSHOULD BE APPROPRIATELY QUALIFIED TO OPERATE THE EQUIPMENT.This section provides general information about Safe Torque Off (STO).Two safety functions can be implemented with the inverter: STO and Safe Stop 1 (SS1). In order to meet all aspects of STO and SS1, an external safetycontrol unit should be used.To implement Safe Stop 1 (SS1), the external safety control unit causes the drive to decelerate to rest. Once at rest, it invokes STO in the inverter.Please refer to EN61800-5-2:2007 para 4.2.2.3 for the formal definitions.It is the user’s responsibility to:1) Risk assess the machine.2) Design, implement and assess an appropriate solution for each application to meet all relevant safety requirements.Note: STO is an electronic inhibit intended for use during normal operation of the machine. It is not intended for use during machine maintenance,repair, replacement or other similar activities. For these activities recognised electrical power isolation devices and lock-off procedures should be used.The inverter STO function is a factory-fitted and factory-tested feature. See the section “Safety Warnings and Limitations” on page 8-17.