Parker EME Compax3 device description192-120102 N15 June 2008 293.3.6. C3Sxxx V4In this chapter you can read about:Power supply connector X1 for 3AC 400VAC/480VAC-C3S devices ................................29Braking resistor / high voltage supply connector X2 for 3AC 400VAC/480VAC_C3S devices............................................................................................................................................30Connection of the power voltage of 2 C3S 3AC devices....................................................303.3.6.1 Power supply connector X1 for 3AC 400VAC/480VAC-C3SdevicesBy cyclically switching on and off the power voltage, the input current limita-tion can be overloaded, which will cause a device error.Therefore please wait at least 2 minutes after switching off before you switchthe device on again!PIN Designation1 L12 L23 L34 PEMains connection Compax3SxxxV4 3ACController type S015V4 S038V4 S075V4 S150V4 S300V4Supply voltage Three phase 3*400VAC/480VAC80-528VAC / 50-60HzInput current 3Aeff 6Aeff 10Aeff 16Aeff 22Aeff6A 10A 16A 20A 25AMaximum fuse rating perdevice(=short circuitrating) MCB miniature circuit breaker D** for UL conform operation (see page 15): MCB miniature circuit breaker S273-K.The 3AC V4 – devices must only be operated with three phases!Always switch devices off before wiring them!Dangerous voltages are still present until 5 minutes after switchingoff the power supply!Device protectionCaution!