Page 16 7044-140C November 21, 2011R3100-I ACC Wood InsertQ. Opacity (Smoke)Opacity is the measure of how cleanly your appliance isburning.Opacity is measured in percent:• 100% opacity is when an object is totally obscured bythe smoke column from a chimney, and• 0% opacity means that no smoke column can be seen.As you become familiar with your appliance, you shouldperiodically check the opacity. This will allow you to knowhow to burn as nearly smoke-free as possible (goal of 0%opacity).P. Frequently Asked QuestionsISSUES SOLUTIONSOdor from appliance When first operated, this appliance may release an odor for the first several hours. This iscaused by the curing of the paint and the burning off of any oils remaining from manufacturing.Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down, similar tothe sound produced by a furnace or heating duct. This noise does not affect the operation orlongevity of the appliance.Whirring sound The blower may produce a whirring sound which increases in volume as the speed isincreased.Figure 16.1 - Clear SpaceO. Clear Space• Do NOT place combustible objects within 4 ft (1.2 m) ofthe front of fireplace. Figure 16.1.• Do NOT place combustible objects within 48inches in front of the appliance.• High temperatures may ignite clothing, furniture ordraperies.Fire Risk.WARNINGCLEAR SPACE4 FT (1.2m) INFRONT OF INSERTNOTICE!Do NOT operate a circulating fan within close prox-imity, approximately 4 ft (1.2m), of appliance• Can reverse air flow, blowing hot air into appli-ance cavity.• Can damage appliance blower due to overheat-ing.R. Door ClosingTo operate this unit the way it was designed by the manu-facturer, the door must be sealed. To seal the unit, the frontdoor needs to remain closed during operation.• Grasp metal spring on front door and push doorclosed.• With your hand on the handle of the door, rotate thehandle clockwise, until it will no longer rotate in thatdirection.• This will ensure that the door is properly closed, and willnot allow for any air leakage.DO NOT operate this unit with the firebox door open fora continuous period of time.This appliance was tested to manufacturersspecifications and operating this unit in a matter otherthan specified by the manufacturer will effect theefficiency of this unit.WARNING