Chapter 3 Changing the Library ConfigurationChanging the Short Labels SettingSun StorEdgeô L25 Tape Library and Sun StorEdgeô L100 Tape Library Userís Guide 63Changing the Short Labels Setting 3The Short Labels option controls how many bar code labelcharacters are returned when the host issues a Read ElementStatus command. When Short Labels is set to:ï Off, all of the bar code label characters are returnedï On, only the first six characters of the bar code label arereturnedTo enable or disable Short Labels:1 Access the Configuration screen (see Accessing theConfiguration Screen on page 53).2 Press the Up or Down buttons until Short Labels is highlighted.3 Press Select.4 Use the Up or Down buttons to select the desired Short Labelssetting. The available settings are Enabled and Disabled.5 Press Select.6 To return to the Configuration screen without changing theoption setting, press Cancel.7 Press Main to return to the main screen.Note: The default setting is Disabled.Caution: If you do not return to the main screen afterchanging this setting, your change will not besaved to NVRAM.