19RAM 100 • 1000 • 5500RAMSETwww.ramsetinc.comTerminal # 1 - COMMONLow voltage common.TERMINAL 2 - SAFETYStops the gate from closing.- GATE OPEN - Holds gate open.- GATE CLOSED - Gate stays closed.- GATE OPENING - Gate continues to open.- GATE CLOSING - Gate stops, then opens.The function can be altered with Dip Switch B5(see dip switch configuration). Used with loopdetectors, photo eyes, safety edges...etc.Becomes active with a closed contact to com-mon.Terminal # 3 - CLOSECloses the gate.Used with 3-button stations or pushbuttons.Becomes active with a closed contact to com-mon.Terminal # 4 - FIREBOXOpens the gate with a maintained signal. Usedwith fire dept. key switches & controls. Becomesactive with a closed contact to common. Closesimmediately after the closed contact to commonis removed.Terminal # 5 - EXITOpens the gate.Uses with exit loop detectors, phone entrysystems,keypads, 3-button stations...etc.Becomes active with a closed contact to com-mon.Terminal # 6 - PHANTOMHolds the gate open when the open limit switchis active.Covers the area of a swing gate’s path.Used with loop detectors and photo eyes.Becomes active with a closed contact to com-mon.Terminal # 7 - RADIOOpens, closes and/or stops the gate.Operation depends on dip switch B8 & A1-3 (seedip switch configuration).Used with an RF reciever, pushbutton, keypad...etc.Becomes active with a closed contact to com-mon.Terminal # 8 - EDGEWhen triggered the gate will stop and remainstopped until the detector is cleared. Once thedetector is cleared, the operator will resumenormal operation. If triggered twice during onetravel, the control board will lock up and thealarm will sound for 6 minutes. After 6 minutesthe unit will return to normal operation.Becomes active with a closed contact to com-mon.Terminal # 9 and 10 - LIMIT 1 & LIMIT 2Stops the gate in either the fully open or fullyclosed position.Direction depends on dip switch A4 (see dipswitch configuration).Factory wired and should not be moved.Becomes active with a closed contact to com-mon.Terminal # 11 and 12 - COMMONLow voltage common.Terminal # 13 - 24 VACProvides 24 VAC for peripheral accessories.Terminal # 14 and 15 - MAG1 & MAG2Provides a closed contact when the gate is clos-ing or closed (like a switch).Used with a Magnetic Lock.Needed: A power supply that is rated for themagnetic lock that is being connected. Makesure the power supply is the right voltage andcurrent rating. See wiring diagram on previouspage.TERMINAL 16 - SLOWOnly available on the All Secure rail drive opera-tor.Creates a slow stop using the slow stop switchmounted in the operator.Factory wired and should not be moved.Terminal # 17 and 18 - MOTOR 1 & MOTOR 2Factory wired and should not be moved.Supplies voltage to the motor.Direction depends on dip switch A4 (see dipswitch configuration).Terminal # 19 and 20 - AC HOT & NEUTRAL115 VAC AND 230 VAC to power the operator.Factory wired and should not be moved.TERMINAL STRIP CONNECTIONS