EC9000i Series Scanner User Guide Operating the scannerLight signals and beepsThe scanner’s status is shown through a single, multistate LED (light-emitting diode), which is the light onthe top, front, right-hand side of the unit. The table below describes typical status signals and theirmeanings.During start upSignals Meaning / What to doRed-red-green-green flashingcycle The scanner is being configured by the application. Wait for theapplication to finish configuring the scanner.Red-green flashing cycleRed-amber-green The scanner is connecting to the application. Wait for the scanner toconnect.Green solid The scanner is configured but idle. The scanner is ready.During document scanning and processingSignals Meaning / What to doGreen flashing The scanner is waiting for the user to insert a document into thefeeder.Green flashing with one shortbeepThe scanner read the document successfully.Green-red flashing cycle The scanner is processing the document. Wait for the scanner tofinish.Red flashing and one shortbeepAn error occurred while the scanner was processing the document.Check your PC application for instructions or refer to your localprocedures. If you need more help, contact your distributor (reseller).Red flashing and one long beep An error occurred while the scanner was processing the document orstoring the captured image. Check your PC application for instructionsor refer to your local procedures. If you need more help, contact yourdistributor (reseller).Red flashing and three shortbeepsThe scanner was not able to read the MICR line.A typical document processing / LED cycle1. The LED is Green (Solid): The unit is idle.2. The LED is Green (Flashing): The scanner is waiting for a document to be inserted for scanning.3. The LED is Green/Red (Flashing): The scanning operation is in progress.4. The LED is Green (Solid): The scanning operation is complete. The scanner has returned to itsidle state.©2014 RDM Corporation Page 22