C HAPTER 320 Fast 9600 - 80’-120’ Booms AutoBoom Installation ManualINSTALL THE POWERGLIDE WIRINGWiring ConnectionsFor wiring connections made outside the cab, apply dielectric silicone grease (P/N 222-0000-006) generously onboth the male and female ends of the connectors. Application of the grease will prevent corrosion to the pins andwires.CONNECT THE HARNESS TO THE BOOM FUNCTION CONTROLS1. On the AutoBoom harness cable (P/N 115-0230-003), locate the Left Solenoid connector and connect it to Port4A on the AutoBoom valve.2. Connect the Right Solenoid connector to Port 4B on the AutoBoom valve.FIGURE 9. Machine’s Cylinder Up Wiring3. Install a boom sense adapter cable (P/N 115-0171-546) between the machine’s left cylinder up coil and theconnector.4. Connect the boom sense adapter cable Up connector to the Left Up connector on the AutoBoom harnesscable (P/N 115-0230-003).5. Install a boom sense adapter cable (P/N 115-0171-546) between the machine’s right cylinder up coil and theconnector.6. Connect the boom sense adapter cable Up connector to the Right Up connector on the AutoBoom harnesscable.NOTE: The system will now disengage when Up is pressed on the machine’s controller. The system must beengaged via the AutoBoom controller or field computer screen.CONNECT THE HARNESS CABLE TO THE CONTROLLER CABLE1. Route the harness cable (P/N 115-0230-003) toward the machine’s cab.CAUTIONAlways connect the power cable as the last stepin the wiring process and verify that the powerleads are connected with the correct polarity.Reversing power leads can cause severe damageto the equipment.