Chapter 2: SmartPilot Commissioning 23Enter Dealer Calibration modeAs improper use of the Dealer Calibration settings can seriously impair SmartPilotperformance, we have made entry to the Dealer Calibration mode more difficult.Ensure you follow the instructions in this step carefully.1. Start with the SmartPilot in STANDBY mode.2. Enter DEALER CAL as follows:Note:For more information on SmartPilot settings, refer to Chapter 3:Set the vessel typeWhen you select a vessel type, the SmartPilot automatically selects appropriatedefault values for various other calibration settings.Some of these settings will be checked later in this procedure and the remainedshould not require any adjustment. The default values for each vessel type arelisted onpage 57.ST6001/ST6002 Controllers ST7001 /ST7002 and ST8001/ST8002Controllers• press and hold the standby key for twoseconds to enter the Calibration mode• when the screen shows DISPLAY CAL,press the disp key until you see theDEALER CAL screen• press the auto key: the display willchange to CAL?• press -1 and +1 together to enter DealerCalibration mode• press and hold the standby key for twoseconds to enter the Calibration mode• when the screen shows DISPLAY CAL,press the disp, up or down arrowkey until you see the DEALER CALscreen• press the auto key: the display willchange to CAL?• press -1 and +1 together (ST7001/ST7002) or press up and down arrowkeys together (ST8001/ST8002)to enter Dealer Calibration modeAt the CAL ? screen, press + together to enter DEALER CAL2 sec x3-1 +1orD6322-2(ST8001 & ST8002 only)+