REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it628541150 - rev.1 - 10/07/2017FAULT DIAGNOSIS - RECEIVERNUMBER OF FLASHINGSERROR POSSIBLE CAUSE2 Configuration error SEL_A/SEL_B/EDM Pin 6-8-11 connections on the RX male connector3 Wrong EDM configuration Pin 8 connections on the RX male connector3 3 EDM feedback failure Contact connectors EDM Power Contactors3 3 STATUS input failure Pin 12 connections on the RX male connector3 3 OVERRIDE_1 / OVERRIDE_1 input failure Pin connections 9-10 on the male connector on the RX3 3 SENSOR input failure Pin connections 2-4 on the sensor connectors3 3 3 3 MUTING LAMP FAILURE Connections on the auxiliary lamp connector4 OSSD1 / OSSD2 error 3-4 pin connectors on the male connector on the RX5 MAIN CARD ERROR Contact ReeR after sales service5 5 BASE SHEET (EEPROM) error Contact ReeR after sales service5 5 MAIN CARD ERROR Contact ReeR after sales service6 MAIN CARD (Microcontroller) error Contact ReeR after sales service6 6 GENERIC DEFAULT BOARD ERROR 6-7-8-9-10-11 pin connections on the male connector on the RX6 6 Beam error Contact ReeR after sales service6 6 24VDC power supply overload Eventual short-circuit on OSSD outputs6 6 6 6 LAMP/STATUS over current Short-circuit on pin 12 or auxiliary lamp connector7 Receiving beams failure Contact ReeR after sales service8 Interfering Emitter Detected Verify the presence of another curtain not correctly positioned(see section "Multiple Systems")ÎÎ In SMP, SMPO models in addition to the corresponding led,when the operator connects SAFEGATE to Computer viaUSB, a POP-UP window with the error code appears on themonitor.Light signals