REER S.p.A. - 32 via Carcano - 10153 Torino Italia Internet: www.reer.it - e-mail: info@reer.it638541150 - rev.1 - 10/07/2017Technical SpecificationsTECHNICAL SPECIFICATIONSTECHNICAL FEATURESSafetyType 4 EN 61496-1:2013 IEC 61496-2:2013SIL 3 IEC 61508-1: (ed.2) IEC 61508-2: (ed.2) IEC 61508-3: (ed.2) IEC 61508-4: (ed.2)PL e EN ISO 13849-1:2015Cat. 4 EN ISO 13849-1:2015Resolutions 30 mm – 40 mmRange 0...4 m (Low) / 3...12 m (High)Guarded area height 310 / 460 /610 / 760 / 910 / 1060 / 1210 / 1510 /1660 / 1810 / 1960 / 2110 / 2260 (m)Multibeam 2 / 3 / 4 beamsPower supply 24VDC ± 20%Power consumption 1W (Emitter) / 2W (Receiver)ConnectionsPower supply connector on TX: M12 - 5 pin malePower supply connector on RX: M12 - 12 Pin MaleMuting sensor connectors / Muting lamp / Configuration: M12 – 5-pin FemaleConfiguration Hardware on RX connector S, SM, SMO modelsHardware or software with USB connection <-> PC on SMP, SMPO modelsConductor dimensions 0,25 ÷ 2.5 mm2(0,5 mm2 with length > 20 m / 1 mm2 with length > 50 m)Max link length 100 mSafety Outputs (OSSDs) 2 PNP – 300mA @ 24VDCSTATUS Output PNP – 100mA @ 24VDC (shows the condition of the OSSD outputs)EDM input Available on RX, selectableRestart Auto/Manual Available on RX, selectableResponse time 5,5 ms...28 ms (see model tables)Test input Available on TX, selectableSignals and diagnosticsLED Signals on Emitter and Receiver LabelsModels SM, SMO: Indication of MUTING / OVERRIDE / CURTAIN STATUSwith integrated lamp in the upper RX cap, LED technologyOperating temperature -30°C ÷ +55°CDegree of protection IP 65 and IP 67Section Size (l x h) 50mm x 55mm