U32-10 Regency ® Direct Vent Gas Insert | 25|25maintenanceFAN MAINTENANCEIf your fan requires maintenance or replacement,access to the fan is through the plate on the rearwall of the firebox. NOTE: the unit MUST NOTbe operated without the fan access panelsecurely in place.Caution: Label all wires prior todisconnecting when servicing controls.Wiring errors can cause improper anddangerous operation. Verify properoperation after servicing.Grate screws7) Remove the 2 screws holding the Air IntakeHood to the rear firebox wall and lift out.8) Remove the 10 screws holding the AccessPanel in place.9) Remove the Fan Air Duct by loosening the3 screws, squeeze the sides together toremove.TO REMOVE FAN:1) Turn the unit off and allow it to cool to roomtemperature.2) Unplug or disconnect power source to stove.3) Remove the mesh barrier and glass front (seesection "Standard Flush Door.")4) Remove logs and brick panels, if used.5) Remove the grate by loosening the two screwsand sliding the grate out.6) Remove the burner/front log support assemblyby removing the 2 screws and lifting it out.Replacing fan:Reverse above steps. Hint for pushing fan downonto pins - rub a bit of dish soap on the grommetso it will slide more easily onto the pin.Check to make sure the fan is seated properly onthe pins, this is very important- try to move the fanback and forth, there should be no noise, if thereis check that the grommets haven't come loose.Seal fan access panel using high temperaturesilicone (sparingly).10) Unplug the wires from the fan motor (frominside the stove).11) Lift Fan Assembly off of the 2 pins, tip forwardand pull through firebox opening.12) Disconnect green wire from power cord.