Regency ® L900 Direct Vent Gas Fireplace30INSTALLATION17) Ensure that the new rubber gasket (suppliedwith coil) is properly positioned and installthe new modulating pressure regulator as-sembly to the valve using the screws sup-plied with the kit. Tighten screws securely.18) Install the enclosed identification label to thevalve body where it can be easily seen.19) Attach the LP conversion decal near oron top of the serial no. decal.20) Replace yellow "Natural Gas" label with red"Propane" label.21) Re-install the right side panel and allelectrical connections to the valve. (2 greywires to modulating coil.)22) Remove the left side panel by undoing the8 screws.23) Locate the control box shown below andremove the J9 jumper using needle nosepliers.24) Re-install the left side panel.25) Re-install the rear log support bracket.26) Adjust the burner aeration settings to the LPsettings and install the burners.Front Burner 1/4"Rear Burner 3/8"27) Re-install the grate.28) Re-install the glass door.29) Re-install the right heat shield.30) Continue with completing unit installation.NOTE: Once the unit has been installed;Installer Notice:This instructions must be leftwith the appliance.a) Turn on the gas supply and check forgas leaks.b) Check the inlet and outlet pressures.c) Check operation of flame control usingthe remote control. Refer to FireWizardoperation manual for details.d) Check for proper flame appearance.J9 Jumper LocationJ9 JumperINSTALLATION