Regency ® P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace32MAINTENANCE2) Remove the Cap, and shine a flashlightdown the Flue. Remove any bird nests, orother foreign material.3) Check for evidences of excessive condensa-tion, such as water droplets forming in theinner liner, and subsequently dripping out thejoints, Continuous condensation can causecorrosion of caps, pipe, and fittings. It maybe caused by having excessive lateral runs,too many elbows, and exterior portions of thesystem being exposed to cold weather.4) Inspect joints, to verify that no pipe sectionsor fittings have been disturbed, and conse-quently loosened. Also check mechanicalsupports such as Wall Straps, or plumbers'tape for rigidity.LOG REPLACEMENTThe unit should never be used with broken logs.Turn off the gas valve and allow the unit to coolbefore opening door and carefully remove thelogs. (The pilot light generates enough heat toburn someone.) If for any reason a log shouldneed replacement, you must use the properreplacement log. The position of these logsmust be as shown in the diagrams under LogInstallation.Note: Improper positioning of logs may cre-ate carbon build-up and will severelyalter the unit's performance which isnot covered under warranty.THERMOPILE/THERMOCOUPLE1) Open the Bottom Louvers or Grills. Removethe Top Louver or Grill.2) Remove the Trim Kit, Glass Door, Log Set,Grate and Burner Assembly (see page26).3) Disconnect thermocouple by loosening nutfrom the valve with a 9mm spanner. Dis-connect thermopile by loosening 2 screwsmarked TP on the valve.4) Remove 2 screws from the pilot assemblyand pull up far enough to be able to loosenthe thermocouple or thermopile with a 7/16"spanner. NOTE: the pilot line is very fragile,use caution when pulling it up.5) Drop the thermocouple or thermopile downthrough the extrusion and pull it out of theunit.6) Reinstall the new ones in reverse order.GLASS GASKETIf the glass gasket requires replacement use atadpole glass gasket (Part # 936-155).DOOR GLASSYour Regency ® fireplace is supplied with hightemperature 5mm-Tempered glass & 5mm-Ce-ramic glass. If your glass requires cleaning, werecommend using an approved glass cleaneravailable at all authorized dealers. Do not useabrasive materials.CAUTION & WARNINGS:* Do not clean when the glass is hot.* The use of substitute glass will void all productwarranties.* Care must be taken to avoid breakage of theglass.* Do not strike or abuse the glass.* Do not operate this fireplace without the glassfront or with a cracked or broken glass front.* Wear gloves when removing damaged orbroken glass.* Replacement of the glass panels should bedone by a licensed or authorized service person.GLASS REPLACEMENTIn the event that you break your glass by impact,purchase your replacement from an authorizedRegency ® dealer only. Replacement glass isshipped already installed into the door frame.Reinstall as per Glass Door Installation onpage 22.REPLACEMENT PARTS:Front Door - Tempered (Part# 360-528)Side Door - Tempered (Part# 360-529)Front Door - Ceramic (Part# 360-538)Side Door - Ceramic (Part# 360-539)GOLD-PLATEDACCESSORIESThe 24 carat gold-plated finish requires littlemaintenance, and need only be cleaned with adamp cloth. DO NOT use abrasive materials orchemical cleaners, as they may harm the finishand void the warranty. Clean any fi ngerprintsoff before turning the unit on.REMOVING VALVE1) Shut off the gas supply.2) Remove the louvers and trim kit. Removethe front door.3) Remove the logs, embers.4) Remove the grate by lifting straight up.7) Slide the burner assembly away from theorifice and lift out.5) Remove the side brick clip in the top of thefirebox and then slide the Side Brick Panelout. The brick panels are very fragile- handle with care.6) Remove the burner by removing the 4screws.