Regency ® P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace8LOCATING YOURGAS FIREPLACE1) When selecting a location for your stove,ensure that the clearances are met asoutlined on page 9.2) Provide adequate clearances for servic-ing.3) The appliance must be installed on a flat,solid, continuous surface (e.g. wood, metal,concrete). This may be the floor, or raised upon a platform to enhance its visual impact.If the appliance is going to be installed oncarpeting, combustible linoleum tile or othercombustible material other than wood floor-ing, the appliance must be installed on ametal or wood panel extending the full widthand depth of the appliance.4) The Room Sealed Gas Fireplace can beinstalled as follows:Model # PositionA) P121: See ThruB) P131: PierC) P121LC: Left CornerD) P121RC: Right Corner5) This appliance is Listed for bedroom instal-lations when used with a Listed MillivoltThermostat. Some areas may have furtherrequirements, check local codes beforeinstallation.6) The P121/P121LC/P121RC/P131 RoomSealed Gas Fireplace is approved for alcoveinstallations, which meet the clearanceslisted on this page.7) We recommend that you plan your instal-lation on paper using exact measurementsfor clearances and floor protection beforeactually installing this appliance. Have aauthorized inspector, dealer, or installerreview your plans before installation.Note: For Exterior Flue TerminationLocations see page 12..INSTALLATIONA) P121 - See ThruB) P131 - PierC) P121LC - Left CornerD) P121RC - Right Corner