Regency ® P40-1 Direct Vent Gas Fireplace 45MAINTENANCEMAINTENANCECAUTION: Wear gloves whenremoving damaged or brokenglass.WARNING: Do not operate theappliance with the glass panelsremoved, cracked or broken.Replacement of the glass panelsshould be done by a licensed orqualifi ed service person.DOOR GLASSYour Regency ® fireplace is supplied with hightemperature 5mm-Ceramic glass. If your glassrequires cleaning, we recommend using anapproved glass cleaner available at all authorizeddealers. Do not use abrasive materials.CAUTION & WARNINGS:* Do not clean when the glass is hot.* The use of substitute glass will void all productwarranties.* Care must be taken to avoid breakage of theglass.* Do not strike or abuse the glass.* Do not operate this fireplace without theglass front or with a cracked or broken glassfront.* Wear gloves when removing damaged orbroken glass.* Replacement of the glass panel(s) should bedone by a licensed or qualified service person.GLASS REPLACEMENTIn the event that you break your glass by impact,purchase your replacement from an authorizedRegency ® dealer only.Replacement glass is shipped already installedinto the door frame. Reinstall as per Glass DoorInstallation in "Standard Flush Door" section.1) Unplug the power source.2) Remove the power module by lifting it upoff of the velcro and pull out.Power Module3) Undo the wire holder by releasing tab.4) Remove the Control module by lifting it upand off to the side.5) Unplug the J1, J2 and J3 harness at the ECSmodule and pull out the Control module.Control Module6) Remove the fan ground wires.7) Disconnect the brown and blue wiresconnected to the J1 harness.8) Release the 2 wire tabs.9) Remove both fans by lifting up off of thepins and tilt sideways and then slide to theleft of the firebox and pull out carefully.10) Reverse steps to re-install.NOTE: To facilitate easier re-installation of thefans, apply some lubricante to the rubber grom-mets at the base of the fan bracket.FAN REPLACEMENTJ1 J2 J3