Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 31OPERATINGINSTRUCTIONS1) Read and understand these instructionsbefore operating this appliance.2) Check to see that all wiring is correct andenclosed to prevent possible shock.3) Check to ensure there are no gas leaks.4) Make sure the glass in the door frame isproperly positioned. Never operate the ap-pliance with the glass removed or withbroken glass.5) Verify that the venting and cap are unob-structed.6) Ensure that the brick panels are installed.7) Verify log placement. If the pilot cannot beseen when lighting the unit, the logs havebeen incorrectly positioned.8) The unit should never be turned off, and onagain without a minimum of a 60 secondwait.OPERATING INSTRUCTIONSLIGHTINGPROCEDUREIMPORTANT: Gas cock knob cannot beturned from "PILOT" to "OFF" unless it ispartially depressed.1) Turn burner OFF using "ON/OFF" switch.OPTIONALREMOTE CONTROLUse the Regency Remote Control Kit approvedfor this unit. Use of other systems may void yourwarranty.The remote control kit comes with a hand heldtransmitter, a receiver and a wall mountingplate.1) Choose a convenient location on the wall toinstall the receiver and the receptacle box(protection from extreme heat is very im-portant). Run wires from the fireplace tothat location. Use Thermostat Wire Table.2) Connect the two wires to the gas valve.See diagram below.CAUTIONDo not wire millivoltremote control wiresto 120V wire.3) Install 3 AAA alkaline batteries in transmitterand 4 AA alkaline batteries in the receiver.Install the receiver and its cover in the wall.Switch the remote receiver to "remote"mode. The remote control is now ready foroperation.OPTIONALWALL SWITCH1) Run the supplied 15' of wire through theright or left side gas inlet opening. Be carefulnot to damage wire.Note: We recommend a maximum of 15'of wire but if you wish to go with alonger run, use the ThermostatWire Table.2) Connect the wire to the supplied wall switchand install into the receptacle box.CAUTIONDo not wire millivoltwall switch wireto 120V wire.OPTIONALWALL THERMOSTATA wall thermostat may be installed if desired,connect the wires as per the wiring diagram.Use table below to determine the maximum wirelength.Note: Preferable if the thermostat is in-stalled on an interior wall.Regency offers an optional programmable ther-mostat but any 250-750 millivolt rated non-anticipator type thermostat that is CSA, ULC orUL approved may be used.CAUTIONDo not wire millivoltwall thermostat wiresto 120V wire.14 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length(Two-Wire) When Using WallThermostat (CP-2 System)Wire Size Max. LengthThermostat Wire TableIMPORTANTTo ignite or reignite the pilot,you must first release thetension springs below the door.Only when the pilot holds, without pressurebeing applied to the control knob, reapply thetension springs to the door. The unit mustnot be operated with the tension springsunattached.