E-5ENGLISHPREPARING THE INSTALLATIONMH040FXA2B/MH040FXA2CIndoor unit Outdoor unit Power supplyØ, V, Hz020/023/026/035 MH040FXA2BMH040FXA2C 1,220-240, 50Unit Outside diameterLiquid Gas020/023/026/035 1/4" 3/8"MH040FXA2B/MH040FXA2C outdoor unit cannot be connected to the following indoor unit combination.-052/MHFMA/MHFEA/MHFUAPiping outside diameter200 mmor more160 mmor more100 mmor more(h) (H)A B600 mmminimum1 Room maxlength2 Room total maxlengthMax height betweenindoor unit & outdoor unitMax height betweenindoor unitsDimension 20m 30 m 15m 7.5 mComposition A,B A+B (H) (h)Piping length and the height300 mmminimum300 mmminimum600 mmminimumCAUTION:3 m as minimum pipe length: It will reducenoise and vibration.This value must be increased at 7.5 meters incase it is connected just one indoor unit.System can work with one indoor unit connected, but it is recommended that the TOTAL number ofindoor unit suggested by manufacturer are connected to obtain the maximum performance.The appearance of the unit may be different from the diagram depending on the model.Make at least one round:It will reduce noise and vibrationThe appearance of the unit may be different from the diagram depending on the model.09'FJM_OUTDOOR_28896A_IM_E_11.23.09.indd 5 2009-11-24 9:19:17