PLC-WM4500/WM4500L Basic Serial Command Functional Specifications15/266.27 IMAGE CommandCommand “C27” [CR]Detail Switch Image Setting statusAcceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.28 Direct on SET CommandCommand “C28” [CR]DetailEnable Direct onThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.29 Direct on CANCEL CommandCommand “C29” [CR]DetailDisable Direct onThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.30 POWER MANAGEMENT READY CommandCommand “C2A” [CR]DetailSet Power Management function to ready statusThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.31 POWER MANAGEMENT CANCEL CommandCommand “C2B” [CR]DetailSet Power Management function to off statusThis status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.32 POWER MANAGEMENT SHUTDOWN CommandCommand “C2E” [CR]DetailSet Power Management function to Shutdown mode.This status is stored in EEPROM and retained regardless of Power OFF/ONoperation.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]