PLC-WM4500/WM4500L Basic Serial Command Functional Specifications17/266.39 POINTER LEFT CommandCommand “C3B” [CR]DetailMove the Pointer of On-Screen Display Menu to the leftThis command works differently from the command by Point button “<” of theprojector or remote control and has no “Volume -” function.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.40 POINTER UP CommandCommand “C3C” [CR]DetailMove up the Pointer of On-Screen Display MenuThis command works the same way as “▲” button of the projector or remotecontrol.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.41 POINTER DOWN CommandCommand “C3D” [CR]DetailMove down the Pointer of On-Screen Display Menu.This command works differently from the command by “▼” button of the remotecontrol and has no “Mute”Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.42 ENTER CommandCommand “C3F” [CR]Detail This command works the same way as “SELECT” button of the projector andremote control.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.43 FREEZE ON CommandCommand “C43” [CR]DetailFreeze on-screen imageThis command works the same way as “FREEZE” button of the remote control forFreeze ON, but does not work for Freeze OFF.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]6.44 FREEZE OFF CommandCommand “C44” [CR]DetailCancel Freeze modeThis command works the same way as “FREEZE” button of the remote control forFreeze Off, but does not work for Freeze ON.Acceptable [ACK] [CR]ResponseUnacceptable “?” [CR]