PLC-WM4500/WM4500L Basic Serial Command Functional Specifications9/266. Functional Execution Command6.1 FormatPC issues a command in the following format:“C” Command [CR]Command: two characters (See Functional Execution Command Table)Projector decodes the received data and returns the result when getting ready to receive thenext command.[ACK] [CR] (0x06, 0x0D) When received Functional Execution Commands.When received data cannot be decoded, “?” [CR] is returned.6.2 When the command pipelining is neededIn the case of the function requiring command pipelining, such as “Volume +/-“ and “Zoom +/-“,operation should follow the same way as in remote control:1) Sending-side system issues commands every 100 ms after receiving the return value.2) When receiving an applicable command, the function is executed for 120 ms from themoment.3) When receiving the same command in sequence within 120 ms, the function is executed foranother 120 ms from the moment of the second command reception.4) When any other command is not received after 120 ms, the execution of pipelining is stopped.5) When Projector receives another command within 120 ms, the execution of pipelining isstopped.6.3 Transfer ExampleChange Projector mode to Video with Basic Command.CommandPC Projector “C” “0” “7” CRProjector PC ACK CRProcessing(A few ms - 5 s