● Adjustments after Parts Replacement (Optical Parts)- 66 -● : Adjustment necessary ❍ : Check necessary■ Optical AdjustmentsContrast adjustmentR-Contrast adjustment(Polarized glass) ● ● ● ●G-Contrast adjustment(Polarized glass) ● ● ● ●B-Contrast adjustment(Polarized glass) ● ● ● ●Integrator lens in adjustment-1 ❍ ❍ ● ●Integrator lens in adjustment-2 ❍ ❍ ● ● ❍ ❍Integrator lens out adjustment ❍ ❍ ● ● ❍ ❍Condenser lens adjustment ❍ ❍ ❍ ❍ ● ❍Relay lens adjustment ❍ ❍ ❍ ❍ ❍ ●Prism PBS adjustment ❍ ❍ ● ● ❍ ❍Focus of LCD panel adjustment ● ●Convergence adjustment ❍ ●Common center adjustment ● ●Panel luminance adjustment ● ●White balance adjustment ❍ ❍Color shading correction ❍ ❍Panel ghost timer reset (✻) ● ●Optical AdjustmentsLCD/PrismAss’yLCDpanelIntegratorLens-inIntegratorLens-out&PBSPolarizedglassR G B R G BOptical filter(HCP) CondenserlensRelayLensDisassembly / Replaced PartsBe sure to reset the Panel Ghost Timer after the LCDpanels or the LCD panel/prism ass'y are replaced tonew one. When the panel ghost timer is reset, the visi-ble ghost position will be optimized.Input mode and signal Not designated1. Enter the service mode.2. Set the each data value of the replaced panel to"10", the panel ghost timer is reset.Group No. Replaced Panel972 - 1 Red panel972 - 3 Green panel972 - 5 Blue panelElectrical Adjustments(✻) Panel Ghost Timer Reset