PLC-XU4000 Expand Serial Command Functional Specifications68 / 749.11.19 CR_SECURITY CommandCommand “CR_SECURITY” [CR]Details Get Security Mode setting statusAcceptable “000_%1[CR]%1 “ON” ------------- PJ Lock setting on Menu is ON-1 or ON-2“OFF” ------------PJ Lock setting on Menu is OFFResponseUnacceptable “Error Code” [CR]9.11.20 CR_KEYDIS CommandCommand “CR_KEYDIS”(CR)Details Get disability status of RC/Projector keys (valid or invalid)Acceptable “000_%a”[CR]%a“NONE” -------------------------- RC / Projector keys are valid“RC” ------------------------------ RC keys are invalid“KEY” ----------------------------- Projector keys are invalidResponseUnacceptable “Error Code” [CR]9.11.21 CR_PJLOCKNOW CommandCommand “CR_PJLOCKNOW” [CR]Details Get if PJ lock is actually in operationAcceptable “000_%1[CR]%1“LOCK” ------------- PJ Lock is in operation. PJ Lock status is ON-1or ON-2 on Menu, and PJ PIN CODE is notentered so that projector is actually locked.“FREE” ------------- PJ Lock is released. PJ Lock status is OFF, or,status is ON-1 or ON-2 on Menu but PJ PINCODE is entered correctly so that PJ Lock isreleased.ResponseUnacceptable “Error Code” [CR]9.11.22 CR_PJLOCKMENU CommandCommand “CR_PJLOCKMENU” [CR]Details Get status of PJ Lock on MenuAcceptable “000_%1[CR]%1“ON1” ------------- PJ Lock status is On-1“ON2” ------------- PJ Lock status is On-2“OFF” ------------- PJ Lock status is OFFResponseUnacceptable “Error Code” [CR]9.11.23 CR_FANMODE CommandCommand “CR_FANMODE”[CR]Details Get selected Fan modeAcceptable “000_%a”[CR]%a “L1” ----------------------- Fan mode is L1“L2” ----------------------- Fan mode is L2ResponseUnacceptable “Error Code” [CR]