PLC-XU4000 Basic Serial Command Specifications22/237.5. Input Mode Read CommandCommand “CR1” [CR]Detail Get the selected Input No.Acceptable “%1” [CR]%1”1” = Computer 1 is selected”2” = Computer 2 is selected“3” = Video is selected“4” =S-video is selectedResponseUnacceptable “?” [CR]7.6. Lamp Time Read CommandCommand “CR3” [CR]Detail Get the total lamp running hours (Not actual lamp used hour, but Eco modecorresponding value).Acceptable “%1” [CR]%1 Shows the time period with 5 digits numbers.Example “00410”[CR] shows 410 hoursResponseUnacceptable “?” [CR]7.7. Setting Read CommandCommand “CR4” [CR]Detail Get screen setting status such as Ceiling / Rear.Acceptable “%1” [CR]%1“11”[CR] = Normal Screen Setting“10”[CR] = Picture is top/bottom reversed.(Status: Rear Ceiling ON)“01”[CR] = Picture is left/right reversed. (Status: Rear ON)“00”[CR] = Picture is top/bottom and left/right reversed.(Status: Ceiling ON)ResponseUnacceptable “?” [CR]7.8. Temp Read CommandCommand “CR6” [CR]DetailGet the temperature data inside the projector.With some temperature sensors installed in the projector, it is possible to get allthe temperature at once.Acceptable “%1_%2_%3” [CR]%1%2%3%1 Temperature of sensor 1%2 Temperature of sensor 2%3 Temperature of sensor 3Temperature data is shown as “00.0”.When the temperature goes down to -, the first characterbecomes “-” instead of a space, like “-05.5” [CR].When no temperature data can be returned due to hardwareproblems, the first character becomes “E” like”E00.0” [CR].When several temperature sensors are equipped, Responses arereturned continuously.“_31.5 _ _35.2 _ _33.4”[CR]The first data is sensor 1, then one space, and the data of sensor2 follows.ResponseUnacceptable “ ”[CR]