4 – Operation26 TASCAM DM-24 AutomationWrite To End:When the Write Revert Time is set to ∞s, you areessentially telling the automation system to maintainthat control’s last setting from the point when auto-mation recording ends, all the way to the end of theprogram.This is called Write To End. In this case, any switchevents existing in the time between the end of auto-mation recording and the end of the program will beerased.NOTEA Write/Trim To End operation must be completed bystopping the time code. Manually disabling Write orTrim mode while time code is running will not performa Write To End operation.AUTO REVERT must be enabled to use Write To End.See the diagram below to understand this Write toEnd behavior:Figure 19 – Writing a new switch event with Write To End enabled.8 sec8 sec8 sec+12+6+30-3-6-12+12+6+30-3-6-121 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec-9+12+6+30-3-6-121 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec-9Existing Switch EventsNew Switch EventsResulting Switch EventsSwitch ONSwitch ONSwitch ON Switch ONSwitch OFFStop Time CodeSwitch OFFSwitch OFFSwitch OFF