Operator's Manual Second Edition • First PrintingInspections42 Z®-60 DC • Z®-60 FE Part No. 1292373GTAt the Platform Controls25 Turn the key switch to platform control.26 Pull out the red Emergency Stop button to theon position.27 FE models: Start the engine. See OperatingInstructions section.Test Emergency Stop28 Push in the platform red Emergency Stopbutton to the off position.Result FE models: The engine should turn off.29 Activate each function control handle, toggleswitch or thumb rocker switch.Result: No functions should operate.30 Pull out the platform red Emergency Stopbutton to the on position.Test the Horn31 Press the horn button.Result: The horn should sound.Test the Foot SwitchDC Models:32 Do not press down the foot switch. Test eachmachine function.Result: No functions should operate.FE Models:33 Push in the platform red Emergency Stopbutton to the off position.34 Pull out the red Emergency Stop button to theon position and do not start the engine.35 Do not press down the foot switch and attemptto start the engine by moving the machinemode select switch to hybrid mode.Result: The engine should not start.36 Move the machine mode select switch to hybridmode.37 Press and hold the foot switch.Result: The engine should start.38 Do not press down the foot switch and testeach machine function.Result: No functions should operate.