VIRDI 4000 TM User’s Manual 38UNION COMMUNITY Co., Ltd. 44-3 Hyundai Topics Building, Bangi-dong,Songpa-gu, Seoul, Korea 138-050, Tel: 82-2-6488-3000, Fax: 82-2-6488-3099,E-Mail:sales@unioncomm.co.kr, http://www.unioncomm.co.kr/eng3.5.3. Doorlock settingsIn the main menu, press [3] to select “3. Option” and the following screenappears:1. Application2. Verify Option3. Set Doorlock4. Sound Control5. Time Setting6. Other SettingPress [3] for door settings.3.5.3.1. Door opening time settings.◆ [*] [3] ◆[3](00-30):03Default setting: ‘03’ (unit: sec.)This is used to set the door opening time after authentication is successful.This only applies to the door opening time for strike type locks and notapplicable to dead bolt type locks or automatic doors.If set to ‘00’, the door in access control mode is not controlled. Therefore, the‘00’ setting is only possible for time & attendance mode, where there’s noneed for lock control.After this setting is complete, press [ENTER] to move to the next setting.3.5.3.2. Door status monitor◆ [*] [3] [3] [ENTER] ◆[0/1=NO/2=NC]:0Default setting: ‘0’- ‘0’: NW – No monitoring- ‘1’: NO – Dead bolt type lock or automatic door- ‘2’: NC - Strike type lock‘0’ setting is for no monitoring, ‘1’ setting is for dead bolt type locks or