9.ERROR CODE979. ERROR CODE9-1. Error Code and Error Assistance CodeThe Error Code contains error related to: Calibration error, Weight error (LOAD,OFL, or Zero Error), and sequence error. In error free state, both of these tworegisters are set to “0”.Error Assistance Code indicates the type of error: “1” for calibration errors, “2”for weight errors, and “3” for sequence errors.Error codes are summarized in the table below.If multiple of errors occur simultaneously, smaller number of Error Code andError Assistance Code has the priority.Calibration Error (Error Assistance Code =1)Weight Error (Error Assistance Code =2)Name Description Error CodeCalibration Error 1 Zero calibration must be performed again 1Calibration Error 2 Initial Tare value exceeds the F159’s zero adjustable range 2Calibration Error 3 Initial Tare value is in negative territory 3Calibration Error 4 Balance weight is larger than Capacity 4Calibration Error 5 Balance weight is set to zero “00000” 5Calibration Error 6 Load cell output falls short of the Lower limit of spanadjustable range 6Calibration Error 7 Load cell output is in negative territory 7Calibration Error 8 Load cell output exceeds the Upper limit of span adjustablerange 8Calibration Error 9 Calibration aborted due to widely fluctuating weight 9Name Description Error CodeEXC ALM Excitation voltage to the load cell falls below the rated value 1+LOAD A/D converter input over-range (to positive direction) 2-LOAD A/D converter input over-range (to negative direction) 3OFL1 Net weight > Net Over set value 4OFL2 Gross weight > Capacity + 9 ×(Minimum scale division) 5OFL3 Gross weight > Gross Over set value 6Zero Error Zero error 7