7.LADDER DIAGRAM887. LADDER DIAGRAMThe following is a sample ladder program using a F159 (unit No.0) and CJ1series. This program sets initial values to parameters required to carry outweighing process, and writes and reads Final using R/W and request signal.A200.11000000 MOV(021)#0D20000Weighing setting data(000000)Upper limitMOV(021)#0D20001 Upper limitMOV(021)#0D20002 Lower limitMOV(021)#0D20003 Lower limitMOV(021)#0D20004 Near zeroMOV(021)#0D20005 Near zeroMOV(021)#0D20006 Set point 1MOV(021)#0D20007 Set point 1MOV(021)#0D20008 Set point 2MOV(021)#0D20009 Set point 2MOV(021)#0D20010 FF CPS.MOV(021)#0D20011 OverMOV(021)#0D20012 Underwrite(lower 4 digits)(upper 1 digit)(lower 4 digits)(upper 1 digit)(lower 4 digits)(upper 1 digit)(lower 4 digits)(upper 1 digit)(lower 4 digits))(upper 1 digit)P_First_CycleON flag is set to allowsingle cycle execution