NOTE!If the 2 activation signals are active at the same time, the drive stops.P3.3.6.4 JOGGING REFERENCE 1 (ID 1239)Use this parameter to set the frequency references for the jogging function.With the parameters P3.3.6.4 and P3.3.6.5, you can set the frequency references for thejogging function. The references are bi-directional. A reverse command does not have aneffect on the direction of the jogging references. The reference for the forward direction hasa positive value, and the reference for the reverse direction has a negative value. You canactivate the jogging function with digital input signals or from Fieldbus in bypass mode withControl Word bits 10 and 11.P3.3.6.5 JOGGING REFERENCE 2 (ID 1240)Use this parameter to set the frequency references for the jogging function.With the parameters P3.3.6.4 and P3.3.6.5, you can set the frequency references for thejogging function. The references are bi-directional. A reverse command does not have aneffect on the direction of the jogging references. The reference for the forward direction hasa positive value, and the reference for the reverse direction has a negative value. You canactivate the jogging function with digital input signals or from Fieldbus in bypass mode withControl Word bits 10 and 11.P3.3.6.6 JOGGING RAMP (ID 1257)Use this parameter to set the ramp time when jogging is active.This parameter gives the acceleration and deceleration times when the Jogging function isactive.10.5 RAMPS AND BRAKES SETUP10.5.1 RAMP 1P3.4.1.1 RAMP 1 SHAPE (ID 500)Use this parameter to make the start and the end of the acceleration and deceleration rampssmoother.With the parameters Ramp 1 Shape and Ramp 2 Shape, you can make smoother the startand the end of the acceleration and deceleration ramps. If you set the value to 0.0%, you geta linear ramp shape. The acceleration and deceleration act immediately to the changes inthe reference signal.When you set the value between 1.0% and 100.0%, you get an S-shaped acceleration ordeceleration ramp. Use this function to reduce mechanical erosion of the parts and currentspikes when the reference changes. You can modify the acceleration time with parametersP3.4.1.2 (Acceleration Time 1) and P3.4.1.3 (Deceleration Time 1).PARAMETER DESCRIPTIONS VACON · 235LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/ 10