Control unit vacon • 6566.2.1 Prepare for use through ethernet6.2.1.1 Ethernet cable dataFigure 56.Leading the cables, left: IP21, right: IP54Table 21. Ethernet cable dataConnector Shielded RJ45 connector; NOTE: Maxlength of the connector 40mm.Cable type CAT5e STPCable length Max .100m1 Connect the Ethernet cable (see specification on page 65) to its terminal and runthe cable through the rubber grommets as other I/O cables.2Protection class IP21: Cut free the opening on the AC drive cover for the Ether-net cable.Protection class IP54: Cut the rubber grommets open to slide the cablesthrough. Should the grommets fold in while inserting the cable, just draw thecable back a bit to straighten the grommets up. Do not cut the grommet open-ings wider than what is necessary for the cables you are using.IMPORTANT: To meet the requirements of the enclosure class IP54, the connec-tion between the grommet and the cable must be tight. Therefore, lead the firstbit of the cable out of the grommet straight before letting it bend. If this is notpossible, the tightness of the connection must be ensured with insulation tape or acable tie.9068.emfPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com