143 Product descriptionVEGAPULS 69 • Modbus and Levelmaster protocol47252-EN-180627• Not in the open• Dry and dust free• Not exposed to corrosive media• Protected against solar radiation• Avoiding mechanical shock and vibration• Storage and transport temperature see chapter "Supplement -Technical data - Ambient conditions"• Relative humidity 20 … 85 %With instrument weights of more than 18 kg (39.68 lbs) suitable andapproved equipment must be used for lifting and carrying.3.4 Accessories and replacement partsThe display and adjustment module PLICSCOM is used for measuredvalue indication, adjustment and diagnosis. It can be inserted into thesensor or the external display and adjustment unit and removed atany time.The integrated Bluetooth module (optional) enables wireless adjust-ment via standard adjustment devices:• Smartphone/tablet (iOS or Android operating system)• PC/notebook with Bluetooth USB adapter (Windows operatingsystem)You can find further information in the operating instructions "Displayand adjustment module PLICSCOM" (Document-ID 36433).The interface adapter VEGACONNECT enables the connection ofcommunication-capable instruments to the USB interface of a PC. Forparameter adjustment of these instruments, the adjustment softwarePACTware with VEGA-DTM is required.You can find further information in the operating instructions "Interfaceadapter VEGACONNECT" (Document-ID 32628).The protective cover protects the sensor housing against soiling andintense heat from solar radiation.You will find additional information in the supplementary instructionsmanual "Protective cover" (Document-ID 34296).Screwed flanges are available in different versions according to thefollowing standards: DIN 2501, EN 1092-1, BS 10, ASME B 16.5,JIS B 2210-1984, GOST 12821-80.You can find additional information in the supplementary instructionsmanual "Flanges according to DIN-EN-ASME-JIS".Electronics module "VEGAPULS series 60" is a replacement part forradar sensors of VEGAPULS series 60. A different version is availablefor each type of signal output.You can find further information in the operating instructions "Elec-tronics module VEGAPULS series 60" (Document-ID 36801).Storage and transporttemperatureLifting and carryingPLICSCOMVEGACONNECTProtective coverFlangesElectronics module