7510 SupplementVEGAPULS 69 • Modbus and Levelmaster protocol47252-EN-180627Vessel pressureƲ Metal-jacketed lens antenna -1 … 3 bar (-100 … 300 kPa/-14.5 … 43.5 psig)Ʋ Plastic horn antenna -1 … 2 bar (-100 … 200 kPa/-14.5 … 29.1 psig)Ʋ Plastic horn antenna, Version withadapter flange from DN 100 PP orPP-GF 30-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)Ʋ Thread with integrated horn antenna -1 … 20 bar (-100 … 2000 kPa/-14.5 … 290.1 psig)Mechanical stressVibration resistance: Metal jacketed lensantenna4 g at 5 … 200 Hz according to EN 60068-2-6 (vibrationwith resonance)Vibration resistance: Plastic horn antennaƲ With adapter flange 2 g at 5 … 200 Hz according to EN 60068-2-6 (vibrationwith resonance)Ʋ with mounting strap 1 g at 5 … 200 Hz according to EN 60068-2-6 (vibrationwith resonance)Vibration resistance: thread with inte-grated horn antenna4 g at 5 … 200 Hz according to EN 60068-2-6 (vibrationwith resonance)Shock resistance 100 g, 6 ms according to EN 60068-2-27 (mechanicalshock)Data on rinsing air connectionRecommended max. pressure with con-tinuous rinsing1 bar (14.50 psig)Max. permissible pressure 6 bar (87.02 psig)Air quality FilteredAir volume, depending on pressureMetal-jacketed lens antenna Air volumePressure Without reflux valve With reflux valve0.2 bar (2.9 psig) 1.7 m3/h -0.4 bar (5.8 psig) 2.5 m3/h -0.6 bar (8.7 psig) 2.9 m3/h 0.8 m3/h0.8 bar (11.6 psig) 3.3 m3/h 1.5 m3/h1 bar (14.5 psig) 3.6 m3/h 2 m3/h1.2 bar (17.4 psig) 3.9 m3/h 2.3 m3/h1.4 bar (20.3 psig) 4 m3/h 2.7 m3/h1.6 bar (23.2 psig) 4.3 m3/h 3 m3/h1.8 bar (20.3 psig) 4.5 m3/h 3.5 m3/h2 bar (23.2 psig) 4.6 m3/h 4 m3/hPlastic horn antenna Air volumePressure Without reflux valve With reflux valve0.2 bar (2.9 psig) 3.3 m3/h -