31GM 5000EAB_03266OPERATING MANUALEDITION 04/2016 ORDER NUMBER DOC23444995.6 THE WAGNER ELECTROSTATIC AIR SPRAYING SYSTEMThe nozzle range (chapter 13) provided by WAGNER allows optimum coating results forany application.General criteria for selection of nozzlesFlat jet for large-surface partsRound jet for smaller delicate partsOptions for influencing the jet spray / spray pattern:Description ModificationProduct pressure + or -Atomizing air pressure + or -Air regulation from open to closedStop screw product valve from open to closedNozzle sizes Flow rateElectrostatics + or - or off5.6.1 PRESSURE SETTINGS FOR ROUND JET NOZZLESAir regulationclosedAir regulationopenedThere are 4 nozzle sizes, D8, D12, EARV LV and EARV HV available. The air cap and nozzle areadjusted according to size to each other and may not be exchanged. During the calibrationof the product pressure and the atomizing air pressure, the air control lever mustbe in a central position as shown in the photo.Pressure setting Nozzle D8 (small) Nozzle D12 (large) / EARVProduct pressure 0.8 bar to 1.2 bar 0.8 bar to 1.6 barAtomizing air pressure 2.0 bar to 2.3 bar 2.3 bar to 3.0 barThe table contains default values. Depending on the product, conditions and the desiredresult different values are possible or necessary.