28OPERATING MANUALEDITION 07/2014 ORDER NUMBER DOC 23445006.4.2 VENTILATION OF THE SPRAY BOOTHThe GM 5000EAC spray gun must be used as part of a spraying system (Spraypack). Thesystem shown in fi gure B_03158 is only one example of an electrostatic spraying system.Your WAGNER distributor would be happy to assist you in creating a spraying systemsolution that meets your individual needs. You must familiarize yourself with the operatinginstructions and the safety regulations of all additional system components before startingcommissioning.Incorrect installation/operation!Risk of injury and equipment damage.When commissioning and for all work, read and follow theoperating manual and safety regulations for the additionallyrequired system components.WARNINGToxic and/or flammable vapor mixtures!Risk of poisoning and burns.Operate the device in a spray booth approved for the workingproducts.-or-Operate the device on an appropriate spraying wall with theventilation (extraction) switched on.Observe national and local regulations for the outgoing airspeed.WARNINGThe electrostatic hand spraying equipment is for use only in spray areas which correspondwith standard EN 12215.The electrostatic hand spraying equipment has to be locked to the technical ventilationso that the coating product supply and the high-voltage are not effective as long as thetechnical ventilation is not operated with the minimum exhaust air volume flow or a largerexhaust air volume flow.Ensure that the excess coating product (overspray) will be collected up safely.