47B_03453OPERATING MANUALEDITION 07/2014 ORDER NUMBER DOC 2344500Gun flushing1. Switch off control unit.2. Ensure that the product pressure is relieved and shut off the air supply to the gun.3. Connect the cleaning agent supply.With round jet nozzle fitted:4. By means of nozzle spanner, loosen nozzle insert by 1/2 turn.5. Actuate the trigger. Flush the gun thoroughly.6. Relieve the pressure from gun and unit!7. Re-tighten the nozzle insert.8. Clean the spray gun body with a cleaning agent recommended by the manufacturerand dry with a cloth or blow gun.With fl at jet nozzle fitted:4. Dismount AirCoat nozzle and clean separately (see Chapter 7.3.7).5. Actuate the trigger. Flush the gun through thoroughly.6. Relieve the pressure from gun and unit!7. Clean the spray gun body with a cleaning agent recommended by the lacquermanufacturer and dry with a cloth or blow gun.Exploding gas / air mixture!Danger to life from flying parts and burns.Never spray into a closed tank.Ground the tank.DANGERNOTICEFlushing agent in the air duct!Functional faults caused by swollen seals.Discharge current to ground -> no high-voltageAlways point the spray gun down when cleaning.Ensure that neither paint nor cleaning agent enters the air duct.When taking a break from work or when stored for a longer period, the spray gunshould be positioned with the adapter pointing downwards.