19GM 5000EAC.12 34R1R3R2B_03182243R1R3R2EB_0326216OPERATING MANUALEDITION 03/2012 PART NUMBER DOC 23191504.4.2 FUNCTIONS OF THE SPRAY GUNDistance Description1 AirCoat air opens.2 AirCoat air opened and electrostatic (HV)activated.-> Display (2) for „spray current“ on the spraygun ●❍❍❍❍ to ●●●●● activated.3 AirCoat air opened and electrostatic (HV)activated and material valve opened.4 Max way of trigger.• An increase in the tension needed to pull the trigger backwill be felt at the position where the material valve opens.• For spraying without high-voltage, the high-voltage canbe switched off using the operating button (4). Press theoperating button (4) briefly: High-voltage is switched off.The standby display (3) illuminates.• In the event of a malfunction the spray gun switches to„standby“ operating mode and the display (3) illuminates.• The width of the spray jet can be adjusted using the airadjustment (16) (only for flat-jet method).The trigger can be used to activate, one after the other, thevarious functions of the spray gun.When the spray gun is connected to the control unitand the control unit is switched on, the pre-definedrecipe (R1, R2 or R3) is shown on the gun display (2) asfollows.Recipe 1 -> ●❍❍❍❍ R1Recipe 2 -> ●●●❍❍ R2Recipe 3 -> ●●●●● R3Recipe change R1 -> R2 -> R3 -> R1Press the operating button (4) and hold the buttonpressed of at least 2 seconds, then it is advanced by1 recipe.Display (2) -> ●●❍❍❍ = recipe values changed temporarily:The stored recipe values of the previously selected recipenumber are re-loaded from memory by pressing the operatingbutton (4) for 2 seconds.