11PEM-X10102OPERATING MANUALVERSION 03/2014 ORDER NUMBER DOC 23260203 IDENTIFICATION3.1 EXPLOSION PROTECTION IDENTIFICATIONThe EC type examination certificate PTB 12 ATEX 5002 can be found in Chapter 14.4.3.2 PERMISSIBLE DEVICE COMBINATIONSGun type: PEM-X1Manufacturer: J. Wagner AGCH - 9450 AltstättenII 2 D 2mJ 85 °CCE: European Communities0102: Number of notified body which issues the recognition of qualityassurance in productionEx: Symbol for explosion protectionII: Device class II2: Category 2D: Ex-atmosphere dust2mJ: Maximum ignition energy 2 mJ85 °C: Maximum surface temperatureIncorrect use!Risk of injury and damage to the device.Only connect original Wagner devices to the PEM-X1 powderspray gun.WARNINGThe PEM-X1 powder spray gun may only be connected to the control devices listed below:EPG-Sprint X with the corresponding PI-F1/HiCoat ED-F powder injectorEPG-Sprint with the corresponding PI-F1/HiCoat ED-F powder injector*EPG S2 with the corresponding PI-F1/HiCoat ED-F powder injector** The remote control function of the PEM-X1 spray gun is not available when using thesecontrol units.Permissible device combinations for the USA and Canada, see Chapter 14.5 "FM Approval".